FabVector

Industry

Test & Measurement

When the part is the reference, the tolerance on the drawing is the least of it — the question is what it measures next winter.

FabVector machines Test & Measurement parts in MIC-6 Cast Aluminum Plate, Aluminum 6061-T6, Invar 36, from 1 piece, with instant online estimates, engineer-reviewed quotes in 24 hours and NDA-protected files. Delivery with duties handled to the US, Canada, UK and Australia.

Materials
MIC-6 Cast Aluminum Plate, Aluminum 6061-T6, Invar 36
Minimum order
1 piece
Estimate
~60s online
Quote
engineer-reviewed 24h
IP
NDA from upload

What slows this industry down

Instrument parts are the one category where dimensional stability beats initial accuracy. A bracket cut from ordinary rolled plate can hold ±0.005 mm on the CMM and then move as residual stress relaxes over weeks, which shows up as drift the customer will blame on the sensor. That is why MIC-6 cast plate and stress-relieved stock exist, and why a shop that quietly substitutes 6061-T6 to save a few dollars ruins an instrument program. Thermal behaviour is the second trap: a steel mount and an aluminium base on the same optical path move against each other by microns per degree, so material choice is a design decision the machinist has to respect rather than optimise. Volumes are small — often five to fifty — and every one of them is inspected, so the supplier has to be comfortable that measurement time exceeds cutting time.

Typical parts we machine

  • Instrument housings and chassis plates
  • Optical and sensor mounts, adjustment stages
  • Probe bodies, styli holders and adapters
  • Calibration artefacts and reference blocks
  • Linear stage carriages and guide brackets

Certifications & standards

ISO 9001
We understand instrument makers expect ISO 9001-grade material control — no undocumented grade substitution, because the substitution is the failure mode here.
ISO 10360
We report CMM results against the measurement method you specify; ISO 10360 describes how the machine itself is qualified, which we can state for the equipment used on your parts.
EN 10204 3.1
We support EN 10204 3.1 certificates on Invar 36 and cast plate, where the alloy chemistry is exactly what the thermal budget was calculated from.

We understand and support these requirements; certification and documentation scope is confirmed per order.

Questions test & measurement buyers ask

Why do instrument brackets drift after machining, and how is it prevented?
Residual stress in rolled plate relaxes over weeks and the part moves — it measured fine on the CMM and drifts in the field, and the customer blames the sensor. Prevention is material choice: MIC-6 cast plate or stress-relieved stock, symmetric material removal, and finish passes that do not re-stress the surface.
Small quantities, every part inspected — is that economical to buy?
It is when the supplier prices measurement as part of the job: instrument work at 5–50 pieces routinely spends more spindle-adjacent time on the CMM than in the cut, and our quotes state the inspection scope explicitly so you are not paying for it twice via rejects.
Steel or aluminum for a mount holding optics and sensors on one path?
Mixing them on one metrology path costs you microns per degree of temperature change as they expand against each other. Pick one family per path — all 6061, or all steel, or Invar where the budget is tight in the thermal sense — and treat the material list as a design decision the machinist must not "optimise".

CNC machining service by country

Have a part in mind?

Upload CAD or drawings. Eligible CNC work gets an instant estimate; other processes move to engineer review. NDA-protected from the first byte.

Start an RFQ
NDA protected · files encrypted